Forum Post: LVS issues with Hierarchy

$
0
0
Hi All, I have big Analog, small digital block. Most of my design is custom based Analog, done with Virtuoso Schematic and Layout. the small digital blocks, i did digital flow, exported gds and verilog netlist, converted it into CDL for LVS comparison. When I tried to run LVS from Virtuoso using PVS , the first time it failed(Missing NMOS and PMOS) So I had added N-Well surrounding the instance (excluding NMOS), and this time the LVS is clean. But the problem re-occurs when i instantiate this module in new cell, and try to run LVS from that hierarchy. I tried flat LVS run as well. Still same error. My tool details as fllows. Digital flow: Genus 16.10, Innovus 16.1 Virtuoso: 6.17, PVS 15.22 My digital cells Deep-N-Well and i have only single power domain. Do anyone have any rough idea on where should i debug? if need any details, let me know. I will try my level best to put as much as possible Thanks! Aarthy