Forum Post: RE: How to fix *WARNING* The number of errors was detected in Extract Tab: 1 in Calibre QRC run.

$
0
0
Hi Marben 1. "vn" is not specified as a ground net. You are using "Full chip selected nets" mode. This means that only R extraction will be done for net vn. C extraction will be done for all nets Would you please try the following? In "Setup" tab, please enable "Setup Dir" and specify the following path: /home/marben/Desktop/Components/Calibre/PARASITIC/CMOS55LPE_5_00_01_00_LB/CMOS55LPE_5_00_01_00_LB_FuncCmax_Detailed If the above suggestion does not resolve the error, would you please attach the Quantus log file? By the way, you might want to consider using "Coupled" cap mode instead of "Decoupled". The extracted coupling caps will be able to give cross-talk effect during simulation. Best regards Quek