Forum Post: RE: PSS sweep in ADE-XL

$
0
0
I have to sweep a parameter for every corner (for example: tuning voltage of an oscillator). If the sweep is done inside the PSS analysis (=Set up in the Choosing Analyses form), the initial transient is run only at the beginning to get a good starting point for the algorithm. This takes most of the time. If I need to sweep a variable globally to reach the same effect the simulation time increases 15x. I want to avoid that. Since this feature was built already into ADE-L, it has surprised me, that it does not work. I am not sure how to use this recover file. If it is similar to the writefinal option of transient or DC, then I would need to run manually one simulation, save the result for every corner and parameter setting and load it in again. I hope I am wrong in this, because this does not seam a pleasant way.