Forum Post: RE: Getting error while running dpi-c functions with SV code
can u mention that two steps ? I have tried using file list & -f option also..
View ArticleForum Post: RE: Orcad PCB 17.2 Padstack script decimal separator issue
The latest HotFix for 17.20 (013) lists some enhancements: 1687819 ALLEGRO_EDITOR UI_GENERAL Change in Region and Language settings of Windows impacts decimal character in Padstack Editor 1696637...
View ArticleForum Post: RE: Orcad PCB 17.2 Padstack script decimal separator issue
Hi, I can confirm that hotfix 013 fixes this problem. Jan Pieter
View ArticleForum Post: RE: Getting error while running dpi-c functions with SV code
thank u guys for all your help & suggestions ...but now problem is solved ..it is working fine.
View ArticleForum Post: pspice error-less then 2 connection at node
Hello, while simulation in pspice i m getting these error,what is the reason for these errors. ERROR(ORPSIM-15141): Less than 2 connections at node 6_GND_D. ERROR(ORPSIM-15141): Less than 2 connections...
View ArticleForum Post: Pspice error-Node is floating
Hello, while simulation in pspice m getting these error,what can be the for these error?? ERROR(ORPSIM-15142): Node 2_V_SAFE is floating ERROR(ORPSIM-15142): Node 2_V_POS is floating...
View ArticleForum Post: RE: Select cell view from lib manager
Hi Andrew, Thanks for that. In the same way, for eg, C allows it, is it possible to have functions stored into a file, and call them from there, pointing to that file (including the file) ? Best...
View ArticleForum Post: RE: pspice error-less then 2 connection at node
You probably have un-modelled pins, pins on the part have no equivalent connection to pins on the model, or possibly an empty model.
View ArticleForum Post: RE: Pspice error-Node is floating
You are missing a "0" symbol. All circuit nodes in a PSpice (SPICE) circuit must have a DC path to "0". There is a DRC for this in later versions that gets flagged when the netlist gets created. Since...
View ArticleForum Post: Printing all DC operating points of all devices
Hi, I am a beginner in ocean. I have the following ocean script which reports the source current of transistor M3. ;*****************************...
View ArticleForum Post: Simulation of all Diodes with inverted junction-voltage
No matter what diode-model I'm taking or in whatever way I'm measuring, the junction-voltage of the diode always is inverted, meaning that negative voltages are passed through and positive ones are...
View ArticleForum Post: RE: Printing all DC operating points of all devices
Potentially you could use the report() function with the dcOpInfo results to do something similar to what you want. Otherwise I think you'd need to use a foreach() loop on the result of outputs() and...
View ArticleForum Post: RE: Select cell view from lib manager
[quote user="José Cardoso"]In the same way, for eg, C allows it, is it possible to have functions stored into a file, and call them from there, pointing to that file (including the file) ? [/quote]...
View ArticleForum Post: RE: Simulation of all Diodes with inverted junction-voltage
Not enough information to know what tool or version you're using, or what exactly you've tried and what doesn't work... Please provide enough information to explain the problem - clearly if diodes...
View ArticleForum Post: RE: Printing all DC operating points of all devices
Dear Andrew, Thanks for your reply Mohammad
View ArticleForum Post: RE: Select cell view from lib manager
Hi Andrew, Imagine that I have a file with generic functions (for eg, read from files, write to files, etc) and I would like to not have them in my main code, but being able to call them whenever I...
View ArticleForum Post: RE: Select cell view from lib manager
Hi Jose, Yes, you only need to load the functions one time and it shouldn't matter where from. You can set up functions to be autoloaded so that the file(s) that contain the function is loaded...
View ArticleForum Post: Make a copy of the Kit
Hello, I am working on a project where I need to add some custom layers for layout. In order not to mess with the original Kit, I want to make a copy of it and do all the modifications to that copy...
View ArticleForum Post: Minimum Blind/Buried Via Gap (L1-L2 and L11-L12)
I have a design with one buried via L2-L11 and two micro vias (L1-L2 and L11-L12). I do not want my microvias overlapping the buried via, but I don't care if the top and bottom micro-vias overlap for...
View ArticleForum Post: RE: Creating digital buses in ADE XL: awvCreateBus
I am having a similar issue. delay( \ ?wf1 awvCreateBus("D0" list( \ awvAnalog2Digital(v("\\D0\\ " ?result "tran") nil nil 0.6 nil "centre") \ awvAnalog2Digital(v("\\D1\\ " ?result "tran") nil nil 0.6...
View Article