Quantcast
Channel: Cadence Technology Forums
Browsing all 62644 articles
Browse latest View live

Forum Post: RE: Run transient with cmin option but applied to certain...

Thanks for these hints! In my case the design was really very sensitive to parasitic caps, so post-layout simulation was giving unfortunately also a significant performance change. No problems on...

View Article


Forum Post: The usage of the vfreq function in ADE Explorer calculator.

Hi ,all ! I want to use the vfreq function in ADE Explorer calculator to create a curve similar to the one shown in the image below, but I encountered some problems. As shown in the following image,I...

View Article


Forum Post: RE: The usage of the vfreq function in ADE Explorer calculator.

Did you actually run a harmonic balance (hb) analysis? The expression won't work if you did (and you would have to have simulated a lot of harmonics to get a graph as you showed). That looks more like...

View Article

Forum Post: RE: How to fillet a T junction in traces?

Thank you!

View Article

Forum Post: RE: The usage of the vfreq function in ADE Explorer calculator.

Hi ,Andrew Beckett ! Your speculation is entirely correct: the calculator window happens to be covered by the schematic window; the waveform in the example plot is obtained through Fourier Transform....

View Article


Forum Post: RE: The usage of the vfreq function in ADE Explorer calculator.

Qunshan, Presumably you're going to want to do a discrete Fourier transform via the dft() function. I'm not sure what you are aiming for here, but the bottom waveform isn't periodic, so you'd need to...

View Article

Forum Post: Toggle hiCreateButton: is it possible to show button depressed to...

Hi, I have a procedure that sets M1 visible when M1 is non-visible, and vice versa. I am using a form button (hiCreateButton) to ?callback the procedure. I wish to be able to have the button depressed...

View Article

Forum Post: RE: i am using gpdk045 technology and i want to get the value of...

Sorry for the late reply, I have a question, is the previous method that used to measure the equivalent resistance and capacitance as Norton or Thevenin equivalent circuit? For the current source, I...

View Article


Forum Post: RE: i am using gpdk045 technology and i want to get the value of...

Dear Hagar Hendy, [quote userid="574897" url="~/cadence_technology_forums/f/mixed-signal-design/57958/i-am-using-gpdk045-technology-and-i-want-to-get-the-value-of-the-capacitance/1395205#1395205"]I...

View Article


Forum Post: RE: i am using gpdk045 technology and i want to get the value of...

Thank you so much, yes you understood my question, what I want to show you if i understand the steps that you said or not ,and i am doing right or not ? i am trying to do a small signal analysis: for...

View Article

Forum Post: RE: The usage of the vfreq function in ADE Explorer calculator.

Hi ,Andrew I have previously learned about Fourier Transform and I know that it can be divided into four cases based on the continuity/discreteness and periodicity/non-periodicity of the time-domain...

View Article

Forum Post: RE: write placement blockage around cell

Hi, every placed instance in the design has a location attribute. You can read that with dbGet/get_db command, and create the placement blockage. You do not need to worry about the box of the...

View Article

Forum Post: RE: Not able to Invoke XRUN

Hi, Thanks after installing libssl it worked. Regards, Deepak B

View Article


Forum Post: Clarity – Tip of the week: How to set Max edge length for signal...

Max edge length for signal net is also referred to as Signal Net Refinement or SNR . In Clarity 3D Layout, the option to specify Max edge length for signal net is set in the Geometry Options settings...

View Article

Forum Post: Cancel checkout of data.dm file

the data.dm file of a library is checkout and temporarily changed. I would like to cancel this checkout and using the following command: ddCheckin(ddGetObj(Lib"" nil "data.dm") "" "c") However I get...

View Article


Forum Post: ADE Spec Comparison: How to set tolerance?

Hi, the default spec tolerance is 10%, but this is often for me too large. I would like to change to 1% for all outputs, but it looks that I have to do this for each row, and I have >50 outputs. Is...

View Article

Forum Post: RE: New versions of GENNUS and INNOVUS not running on CentOS 9

All the tools are working now. I installed redhat-lsb-core and a couple of other missing packages. Not sure if that was the only reason. The OS was also had to be reinstalled for something else....

View Article


Forum Post: What are the different ways to share a design?

With teams located globally, different functions/blocks of the schematic design are captured by multiple teams. At times, legacy design modification is required and is to be taken up by remote teams....

View Article

Forum Post: RE: Cancel checkout of data.dm file

Jaap, I think the message is coming from DesignSync (a Dassault MatrixOne product), so best to ask them. There appears to be some unofficial way of adding extra arguments, using something like "cx-f"...

View Article

Forum Post: Converting .MAX file to .BRD File issue

Hello, I'm trying to convert a max file into a brd file, currently running v22.10.006. An error message pops up saying "....filename.log' does not exist." I've used this method (Import -> CAD...

View Article
Browsing all 62644 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>