Forum Post: Including parameters in measurement expression

$
0
0
Hello, I have an established parameter, in this case called "CLOAD" when I use it in the schematic program and I need to call it this it can be done with the curly brackets {CLOAD}. I have a mathematical equation that is evaluated in the post processor that helps calculate a value, 1/(10e-9*2*pi*XatNthY(DB(V(AOL_LOADED)),20,1)) This measurement works great and provides the value I want. I would like to change the measurement to be more dynamic. I would like to use the parameter in the measurement equation, like this: 1/( {CLOAD} *2*pi*XatNthY(DB(V(AOL_LOADED)),20,1)) This provides an error, is it possible to call into measurement expressions a parameter value? Note: I am using an AC analysis without parametric stepping. Therefore i=Cdv/dt cannot be used since there is no time component. All the best, Carolina