Quantcast
Channel: Cadence Technology Forums
Browsing all 63526 articles
Browse latest View live

Forum Post: Disable simulator output log autoscroll during simulation

Hi all, I want to know that is there a way to disable autoscroll function when viewing output log file of the simulator during simulation? I want to check the warnings in the first few lines of the...

View Article


Forum Post: RE: Disable simulator output log autoscroll during simulation

I am viewing output log file through "Simulation" -> "Output Log" in ADE Explorer

View Article


Forum Post: RE: Disable simulator output log autoscroll during simulation

In the log file window use File→Auto Update Off (you can turn it back on again with the Auto Update On menu). Andrew

View Article

Forum Post: RE: Allegro Design 17.4 After revising pad stack, what is...

Hello avant , it might be design specific issue. Run the Database Check on the board. I can have a further look into it if you can share the design and pad!!

View Article

Forum Post: setting "max_approach_step" parameter

Hi all, I am running a long transient anaylsis, where I got the following error during the simulation: ERROR (SPECTRE-16928): Cannot run the simulation because transient analysis has reached the...

View Article


Forum Post: RE: setting "max_approach_step" parameter

sorry there's a typo in the title, it should be "max_approach_minstep"

View Article

Forum Post: RE: setting "max_approach_step" parameter

This is a rarely used parameter, and so isn't on the form. You have to go to SImulation→Options→Analog, and then the Miscellaneous tab, and in the Additional arguments field (at the bottom of the...

View Article

Forum Post: RE: setting "max_approach_step" parameter

Hi, Andrew. I tried increasing "max_approach_minstep" a little bit, but that doesn't help much. I am trying diagnostic mode to see if there are any clues. Thank you very much!

View Article


Forum Post: RE: DFA check space of compont to BGA ball or BGA PAD in APD

Hi zpofrp, yes APD can easily create check for bga pin to package. This is done via Manufacturing checks Design For Assembly > Spacing > Component Body to... This looks as shown in the image...

View Article


Forum Post: RE: DFA check space of compont to BGA ball or BGA PAD in APD

I try it, its OK in a new design. But i set it in a old design, it is wrong. There are many dielectrics above the top layer in the old design. There are many d ielectrics below the bottom layer in the...

View Article

Forum Post: RE: Creating a BOM using CIS BOM from someone elses design file...

Properties which are manually added on schematic components, can be added under Report Properties in Select properties section manually on top and then can be added in Output format. For ex: I added...

View Article

Forum Post: RE: how to create smoke parameters in pspice model editor

"Add smoke" feature with Pspice designer license is being worked upon. Currently you can add smoke parameters with 'PSpice Designer Plus' or 'Advanced Analysis' licenses.

View Article

Forum Post: Graphical PCell support

Hi Team, Recently while trying to work with Graphical Pcell, I got a warning in the CIW (snip below). This means, after the Graphical Pcell option is removed, the Pcells created by GUI option won't...

View Article


Forum Post: How to assign signal name to specific PATH automatically

Hi All, I need to assign many signal names to corresponding PATH and LOCATION . The mapping relationship between signal name and PATH are specified in a table. As shown in below picture, the PR? is an...

View Article

Forum Post: RE: DFA check space of compont to BGA ball or BGA PAD in APD

I guess the compont is be placed on d ielectric, for example slod-bot,slod-top/

View Article


Forum Post: RE: Graphical PCell support

Naveen, I think I've been advising customers to not use the graphical PCell environment (i.e. Launch→Plugins→PCell) for a good 25 years, and I'd say it's been our general recommendation to not use it....

View Article

Forum Post: Source setlist references but does not define...

I am trying to run LVS but running into this error for a tsmcN65 stack.. Any ideas on what the issue is?

View Article


Forum Post: RE: Finish current command before starting new command

Hi everyone! I also have same problem. In my skill code , I use ?cmdType "general" mode for pupose use axlShell ("move*******"). How I can finish current allegro editor command before run my skill...

View Article

Forum Post: RE: Source setlist references but does not define...

a) I think that warning is pretty obvious. b) That is not a Cadence LVS tool warning.... So why post on the Cadence Community forum?

View Article

Forum Post: RE: Signal type

Hi Andrew, Thank you for the clarification and sorry for the misleading variable name Best regards Aldo

View Article
Browsing all 63526 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>